ø 42
Split-core current transformer
TQ50-E ../1A
The very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.
250/1A .. 1000/1A
0,5 or 1 or 3
0,5VA or 5VA
Our customers expect us to be able to offer them a solution for every challenge. For which challenge are you looking for a solution?
Aafje Heinhuis, Inside Sales
+31 (0)521 533 333
Order specifications
Burden | Ratio | Class | EAN Code | Article number |
---|---|---|---|---|
0,5VA or 5VA | 250/1A | 1 | 8716479043050 | 4Q5R10 |
0,5VA or 5VA | 300/1A | 1 | 8716479043067 | 4Q5R11 |
0,5VA or 5VA | 400/1A | 0.5 | 8716479043074 | 4Q5R12 |
0,5VA or 5VA | 500/1A | 0.5 | 8716479043081 | 4Q5R13 |
0,5VA or 5VA | 600/1A | 0.5 | 8716479043098 | 4Q5R14 |
0,5VA or 5VA | 750/1A | 0.5 | 8716479043104 | 4Q5R15 |
0,5VA or 5VA | 800/1A | 0.5 | 8716479043111 | 4Q5R16 |
0,5VA or 5VA | 1000/1A | 0.5 | 8716479043128 | 4Q5R17 |
0,5VA or 5VA | 400/1A | 3 | 8716479043302 | 4Q5S12 |
0,5VA or 5VA | 600/1A | 3 | 8716479043319 | 4Q5S14 |
0,5VA or 5VA | 800/1A | 3 | 8716479043326 | 4Q5S16 |
0,5VA or 5VA | 1000/1A | 3 | 8716479043333 | 4Q5S17 |
General Technical Specifications
This product is designed to be safe under the following conditions:
Environmental conditions
Indoor use
IP20
Only suitable for insulated conductors.
Application conditions
IEC 61869-2
60 x Ipr / 1s
1
0,72/3/-kV
50/60Hz
E (120°C)
ø 42
5 meter cable, 0,5 mm2 flexible
CAT IV 600 V
Downloads
The following downloads are available for this product.
Complementary goods
The following products complement this products in its use.
-
UAD6(n)This UAD6 easy voltage tap allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools.400Vac2,5-6mm
-
UAKWith the UAK it is possible to make a safe and simple fused voltage branch in your distribution system.690V10A
-
ZK4-M6/M8With the ZK4-M6/M8 it is possible to make a safe and simple fused voltage branch in your distribution system. _x000D_400Vac2A